Schedule automatic dosage:

Schedule manual dosage:
 |
SINGLE PRODUCT DOSAGE (LOAD)
(manual and automatic control).
Configuration which allows to manage a dosage system in loading of a single product, useful for dividing the quantity of materials of equal weight, for filling hoppers, extracting precise quantities from a silo, guiding the operator in the manual dosages.
Method LOAD: increase of weight of the container to be filled, until the set target weight is reached.
Main Features
- basic functions (clearing, tare, and weight printing)
- selectable dosage mode, either automatic or manually guided
- database of 40 formulas with target, speed change threshold, flight, +/- tolerance and programmable minimum tare and maximum tare values for each formula
- quick switch of the dosage target, through a dedicated key
- dual dosage speed (approximate and fine), managed through active output in constant mode or with bleeding function, with programmable ON/OFF time
- start / pause dosage from keyboard or through enabling of the inputs
- automatic printing of the dosage data
- storage and printing of the consumptions: consumption of each formula, consumption of the formulas, dosed general total; printouts may be quickly recalled from the keyboard
- automatic correction of the flight weight, with degree of programmable incidence
- programmable number of repetitions of the dosage cycle or infinite repetition of the dosage cycle
- checking of the tare presence at the dosage start; the tare values are programmable for each formula
- tolerance test on the dosed weight, with guided correction through simple messages to the display
- analogue output (optional), proportional to the weight or to the dosage speed
- check of the maximum dosage time
- alarm management
Function automatic dosage with load method:
Once the dosage start command is received, the following takes place:
- the presence of the tare and weight stability is verified and the execution of the automatic tare and the enabling of the automation through its dedicated outputs: the dosages start at maximum speed
- once the speed change threshold is reached, the dosage is slown down through the dedicated output.
- when the target is reached, the configured flight weight is missing; the slow dosage output is disabled and then it waits (for the configured time) for the dropping of the material
- tolerance test on the dosed weight
- storage of the formula consumptions and increment of the dosed general total
- complete unloading request, through enabling of dedicated output
- fine dosage or automatic restart for following cycle
|