VPI-CLB Indicator for panel mounting |
|
Software version for the measurement/integration of the flow of material transitioning on the weighing belt, with memorisation of the quantity of dosed material; possibility of adjusting the flow through the 16 bit analogue output and PID control. Possibility of remote management of the instrument, through Sysway or Modbus RTU protocols, or Profibus through optional interface.
|
(Please click on an image to magnify)![]() Indicator VPI-CLB for panel mounting Download leaflet ![]()
Prices exclusive options and VAT. |
FUNCTIONS
The flow reader mode provides for the display of the hourly flow passing on the belt and the display of the status of the system and the accumulated total. By closing the dosage start input, the system waits for the eventual set synchronisation time and enables the dosage output; if the analogue output has been configured, it transmits a signal, in voltage or in current, proportional to the hourly flow; furthermore it is possible to interrogate the instrument through the serial line and configure the setpoints through the fitted Modbus and Sysway protocols or the optional Profibus one. The dosage ends upon reaching the configured target, or by reopening the start input. If a printer is connected, the data of the finished dosage is printed FLOW REGULATOR FUNCTIONING The flow adjuster mode provides for the display of the hourly flow transitioning on the belt and the display of the status of the system and the accumulated total. Furthermore, during the dosage, the instrument adjusts the flow in order to keep it constant equal to the set flow target: if the flow increases, the instrument decreases the value of the analogue output in order to decrease the belt speed or the flow of material extracted from the silo; on the other hand, if the flow decreases, the instrument increases the value of the analogue output in order to increase the belt speed or the flow of material. The adjustment of the flow is obtained through the completely adjustable PID (proportional, integral, derivative) control. By closing the dosage start input, the system waits for the eventual set synchronisation time and enables the dosage output; if the analogue output has been configured, this transmits a signal, in voltage or in current, proportional to the hourly flow; furthermore it is possible to interrogate the instrument through the serial line and configure the setpoints through the fitted Modbus and Sysway protocols or the Profibus one (option). The dosage ends when the set target is reached, or by reopening the start input. Furthermore, it is possible to set a dosage slowing threshold: when this threshold is missing from the weight to be dosed, the instrument slows the system in order to maintain the "slow flow" set until the target is reached. If a printer is connected, the data of the finished dosage is printed. |
| Print page | Home | Close |