MULTICOMPONENT DOSAGE
Description of activities
- Dosage in automatic loading
This activity has the purpose to automatically dose a product; the instrument enables the fast dosage output and the product one: the dosage starts at the maximum speed; when the weight reaches the target to be dosed - slow dosage weight - material weight in flight threshold, the approximate dosage relay disables and the dosage continues in fine mode until the target to be dosed - material weight in flight threshold is reached.
The instrument waits, in the configured time, for the fall of material in flight, executes the tolerance check and stores the data of the executed dosage. In the end, the data of the executed dosage are automatically transmitted through the serial line for the printing or the storage on PC/PLC.
- Dosage in manual loading
This activity has the purpose of manually dosing a product; the instrument enables the fast dosage output and the product one: the dosage starts at the maximum speed; when the weight reaches the target to be dosed - slow weight dosage threshold, the approximate dosage relay disables and the dosage continues in fine mode until the target to be dosed - material weight in flight threshold is reached.
The instrument waits, in the configured time, for the fall of material in flight, executes the tolerance check and stores the data of the executed dosage. In the end, the data of the executed dosage are automatically transmitted through the serial line for the printing or the storage on PC/PLC.
If the optional control light has been connected, the operator can be guided by the three lights in the following way
:
- YELLOW LIGHT: dose in approximate mode
- YELLOW LIGHT + GREEN LIGHT: dose in fine mode
- GREEN LIGHT: once reached the DOSAGE TARGET
- GREEN LIGHT + RED LIGHT: the dosed weight goes within the upper tolerance limit
- RED LIGHT: abundant dosage (out of upper tolerance).
- Total Unloading
This activity has the purpose of completely unloading the scale; the instrument enables the approximate dosage output and the product output and will be disabled when the weight goes below the end unloading threshold.
- Partial Unloading
This activity has the purpose of unloading a precise quantity of material; the instrument enables the fast dosage output and the product one: the dosage starts at the maximum speed; when the weight reaches the target to be dosed - slow weight dosage threshold, the approximate dosage relay disables and the dosage continues in fine mode until the target is reached.
The instrument executes the tolerance check and stores the data of the executed dosage. In the end, the data of the executed dosage are automatically transmitted through the serial line for the printing or the storage on PC/PLC.
- Fractioned Unloading
This activity has the purpose of executing a total unloading, fractioning the material in equal weight quantities, programmable (example: unload 2000kg in 20 dosages of 100 kg). Each single unloading is managed as a partial unloading activity.
- Timer
This activity has the function of enabling, for the programmed time, a relay, which can be connected to a stirrer, a mixer, a burner, or, generally, to a device which should be enabled for a preestablished time and disable itself automatically.
- Pause
A pause allows to interrupt the dosage, in the case that the user must execute an operation; the dosage restarts by supplying a start impulse.
- Manual weight
Allows to sum to the dosage a preweighed quantity of material, counting it in the consumptions, without having to dose it (for example, a bag of dust of 20kg, a tank of additives of 3 kg).
|